Permanent Magnets & Hall Effect Sensors     My Account    |   Track Your Order   |   My Cart    |   F.A.Q.         
    Project Engineering     |     Collaboration Forum     |     Contact Us     |     About Us    |     Site Map       sales@bbautomacao.com


Permanent
Magnets
NdFeb Magnets
Alnico Magnets
SmCo Magnets
H. Ferrite Magnets
Rare Earth Magnets
Bonded NdFeB

Magnet Grades


Project Magnets
Custom Magnets
Industrial Magnets
Motor Magnets
Generator Magnets
Dipole Magnets
Chinese Magnets
Strong Magnets

Neodymium Magnets

Custom Neodymium
Neodymium Rings
Neodymium Bars
Neodymium Blocks
Neodymium Cylinders
Neodymium Discs
Neodymium Spheres
Coated Neodymium

Hall Effect Sensors

Vane Sensors
ICs/Elements
Gear Tooth Sensors
Current Sensors
Voltage Sensors
Analog Sensors
Digital Sensors

Measuring Devices
Gauss/Tesla Meters
Magnetic Fluxmeters
Magnetic Field Viewer


Checkout


Search
Terms & Policies
Magnet manufacturers
Neodymium China

 

 

 
 

Open Loop Hall Effect Current Sensors/Transducers

Current Sensors with Rectangle Windows

  Principle of Open Loop Hall Effect Current Sensors
  Price List of Current Sensors with Rectangle Windows

open loop pcb-based | open loop rectangle window | open loop round window
closed loop pcb-based | closed loop rectangle window | closed loop round window

 

Hall Current Sensors – Open Loop

The Hall Current sensors measure the magnetic field surrounding the conductor (also sensing DC currents). A circular core of soft magnetic material is placed around the conductor to concentrate the field. The Hall element, which is placed in a small air gap, delivers a voltage that is proportional to the measured current.

Open Loop Current Sensors are more affordable than Closed Loop Current Sensors, but the amplified output signal of the Hall element is directly used as the measurement value (resulting in a lower sensitivity). The linearity depends on that of the magnetic core. Offset and drift are determined by the Hall element and the amplifier.

AC/DC Hall Effect Current Sensors

 
Case Type Data sheet Power supply Rated Current Output Signals Accuracy Linearity Operating Temperature Window Sizes (mm)
CYHCS-K3
PDF
HTML
±15V 50A - 600A 0 ~ ±4V 1.0% 1.0% -40°C ~ +85°C 20.5 x 10.5
CYHCS007
PDF
HTML
±15V 50A - 600A 0 ~ ±4V 1.0% 1.0% -10°C ~ +80°C 20 x 10
CYHCS007-B
PDF
HTML
±15V 50A - 600A 0 ~ ±4V 1.0% 1.0% -10°C ~ +80°C 20 x 10
CYHCS007-F
PDF
HTML
±15V 50A - 600A 0 ~ ±4V 1.0% 1.0% -10°C ~ +80°C 20 x 10


 
DC Hall Current Sensors/Transducers
 
Case Type Data sheet Power supply Rated Current Output Signals Accuracy Linearity Operating Temp. Window Size (mm)
CYHCT-E1
PDF
HTML
±12V, ±15V 50A - 600A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 20.5x10.5
CYHCT-A5
PDF
HTML
±12V, ±15V 100A - 500A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 33x11
CYHCT-A5E
PDF
HTML
+12V, +15V, +24V
CYHCT-A5F
PDF
HTML
±12V, ±15V 100A - 500A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 33x11
CYHCT-A5G
PDF
HTML
+12V, +15V, +24V
CYHCT-F7
PDF
HTML
±12V, ±15V 100A - 800A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 41x11
CYHCT-F7E
PDF
HTML
+12V, +15V, +24V
CYHCT-F7F
PDF
HTML
±12V, ±15V 100A - 800A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 41x11
CYHCT-F7G
PDF
HTML
+12V, +15V, +24V
CYHCT-A4
PDF
HTML
±12V, ±15V 300A - 800A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 33x16
CYHCT-A4E
PDF
HTML
+12V, +15V, +24V
CYHCT-A4F
PDF
HTML
±12V, ±15V 300A - 800A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 33x16
CYHCT-A4G
PDF
HTML
+12V, +15V, +24V
CYHCT-C2
PDF
HTML
±12V, ±15V 300A - 1000A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 62x15
CYHCT-C2E
PDF
HTML
+12V, +15V, +24V
CYHCT-C2F
PDF
HTML
±12V, ±15V 300A - 1000A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 62x15
CYHCT-C2G
PDF
HTML
+12V, +15V, +24V
CYHCT-F1
PDF
HTML
±12V, ±15V 300A - 1500A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 51x12
CYHCT-F1E
PDF
HTML
+12V, +15V, +24V
CYHCT-F1F
PDF
HTML
±12V, ±15V 300A - 1500A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 51x12
CYHCT-F1G
PDF
HTML
+12V, +15V, +24V
CYHCT-F2
PDF
HTML
±12V, ±15V 300A - 1500A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 64x16
CYHCT-F2E
PDF
HTML
+12V, +15V, +24V
CYHCT-F2F
PDF
HTML
±12V, ±15V 300A - 1500A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 64x16
CYHCT-F2G
PDF
HTML
+12V, +15V, +24V
CYHCT-C3
PDF
HTML
±12V, ±15V 500A - 2500A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 85x15
CYHCT-C3E
PDF
HTML
+12V, +15V, +24V
CYHCT-C3F
PDF
HTML
±12V, ±15V 500A - 2500A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 85x15
CYHCT-C3G
PDF
HTML
+12V, +15V, +24V
CYHCT-F3
PDF
HTML
±12V, ±15V 600A - 2500A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 104x22
CYHCT-F3E
PDF
HTML
+12V, +15V, +24V
CYHCT-F3F
PDF
HTML
±12V, ±15V 600A - 2500A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 104x22
CYHCT-F3G
PDF
HTML
+12V, +15V, +24V
CYHCT-F6
PDF
HTML
±12V, ±15V 800A - 2500A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 103x36
CYHCT-F6E
PDF
HTML
+12V, +15V, +24V
CYHCT-F6F
PDF
HTML
±12V, ±15V 800A - 2500A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 103x36
CYHCT-F6G
PDF
HTML
+12V, +15V, +24V
CYHCT-C4
PDF
HTML
±12V, ±15V 1000A - 6000A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 125x26
CYHCT-C4E
PDF
HTML
+12V, +15V, +24V
CYHCT-C4F
PDF
HTML
±12V, ±15V 1000A - 6000A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 125x26
CYHCT-C4G
PDF
HTML
+12V, +15V, +24V
CYHCT-C5
PDF
HTML
±12V, ±15V 1000A - 6000A 0~4V, 0~5V 1.0% 1.0% -10°C ~ +80°C 150x40
CYHCT-C5E
PDF
HTML
+12V, +15V, +24V
CYHCT-C5F
PDF
HTML
±12V, ±15V 1000A - 6000A 0~20mA, 4~20mA 1.0% 1.0% -10°C ~ +80°C 150x40
CYHCT-C5G
PDF
HTML
+12V, +15V, +24V
CYHCT-C11
CYHCT-C14

PDF
HTML
±12V, ±15V 5000A - 25000A 0~4V, 0~5V
0-20mA, 4-20mA
1.0% 1.0% -10°C ~ +80°C 182x110 ~ 210x110


 
AC Hall Current Sensors/Transducers
 
Case Type Data sheet Power supply Rated Current Output Signals Accuracy Linearity Operating Temp. Window Size (mm)
CYHCS-F7
PDF
HTML
±12V, ±15V 100A - 800A 0~4V (rms), 0~5V (rms) 1.0% 1.0% -10°C ~ +80°C 41x11
CYHCS-F7E
PDF
HTML
+12V, +15V, +24V
CYHCS-F7F
PDF
HTML
±12V, ±15V 100A - 800A 0~20mA (rms), 4~20mA (rms) 1.0% 1.0% -10°C ~ +80°C 41x11
CYHCS-F7G
PDF
HTML
+12V, +15V, +24V
CYHCS-C2
PDF
HTML
±12V, ±15V 300A - 1000A 0~4V, 0~5V (rms) 1.0% 1.0% -10°C ~ +80°C 62x15
CYHCS-C2E
PDF
HTML
+12V, +15V, +24V
CYHCS-C2F
PDF
HTML
±12V, ±15V 300A - 1000A 0~20mA, 4~20mA (rms) 1.0% 1.0% -10°C ~ +80°C 62x15
CYHCS-C2G
PDF
HTML
+12V, +15V, +24V
CYHCS-F1
PDF
HTML
±12V, ±15V 300A - 1500A 0~4V, 0~5V (rms) 1.0% 1.0% -10°C ~ +80°C 51x12
CYHCS-F1E
PDF
HTML
+12V, +15V, +24V
CYHCS-F1F
PDF
HTML
±12V, ±15V 300A - 1500A 0~20mA, 4~20mA
(rms)
1.0% 1.0% -10°C ~ +80°C 51x12
CYHCS-F1G
PDF
HTML
+12V, +15V, +24V
CYHCS-F2
PDF
HTML
±12V, ±15V 300A - 1500A 0~4V, 0~5V (rmS) 1.0% 1.0% -10°C ~ +80°C 64x16
CYHCS-F2E
PDF
HTML
+12V, +15V, +24V
CYHCS-F2F
PDF
HTML
±12V, ±15V 300A - 1500A 0~20mA, 4~20mA
(rms)
1.0% 1.0% -10°C ~ +80°C 64x16
CYHCS-F2G
PDF
HTML
+12V, +15V, +24V
CYHCS-C3
PDF
HTML
±12V, ±15V 500A - 2500A 0~4V, 0~5V (rms) 1.0% 1.0% -10°C ~ +80°C 85x15
CYHCS-C3E
PDF
HTML
+12V, +15V, +24V
CYHCS-C3F
PDF
HTML
±12V, ±15V 500A - 2500A 0~20mA, 4~20mA (rms) 1.0% 1.0% -10°C ~ +80°C 85x15
CYHCS-C3G
PDF
HTML
+12V, +15V, +24V
CYHCS-F3
PDF
HTML
±12V, ±15V 600A - 2500A 0~4V, 0~5V (rms) 1.0% 1.0% -10°C ~ +80°C 104x22
CYHCS-F3E
PDF
HTML
+12V, +15V, +24V
CYHCS-F3F
PDF
HTML
±12V, ±15V 600A - 2500A 0~20mA, 4~20mA
(rms)
1.0% 1.0% -10°C ~ +80°C 104x22
CYHCS-F3G
PDF
HTML
+12V, +15V, +24V
CYHCS-F6
PDF
HTML
±12V, ±15V 800A - 2500A 0~4V, 0~5V (rms) 1.0% 1.0% -10°C ~ +80°C 103x36
CYHCS-F6E
PDF
HTML
+12V, +15V, +24V
CYHCS-F6F
PDF
HTML
±12V, ±15V 800A - 2500A 0~20mA, 4~20mA
(rms)
1.0% 1.0% -10°C ~ +80°C 103x36
CYHCS-F6G
PDF
HTML
+12V, +15V, +24V

 

Typical Applications

  • General Purpose Inverters

  • AC/DC Variable Speed Drivers

  • Battery Supplied Applications

  • Uninterruptible Power Supplies (UPS)

  • Switched Mode Power Supplies (SMPS)

 


  • ac low current measurement

  • motor current measurement

  • 1 A current sensor

  • max over current protection

  • current sense resistors

  • electrical current measurement examples

  • universal voltage to current transducer

  • ac current sensing theory

  • brushless motor

  • switched power supply

  • power inverters

  • brushless dc generators

  • ultra power supplies

  • linear displacement transducer

  • current measurement circuit

  • sensor transducer

  • Power Supply Design

  • stepping motors

  • current sensors

  • dc/ac inverter

  • brushless dc motor

  • uninterruptible power supply

Have  question? Please Click Here for Support

power_transducer_close_loop_threshold
Engineering Forum

 

 

Home | Products | Search | Checkout | About us | Contact us | Site map

© Copyright BB Automacao Inc.

4 Cedar Swamp Rd.
Glen Cove, New York 11
542
nyc@bbautomacao.com
Ph.: 516-277-1278