Open Loop Hall Effect Current Sensor CYHCT-E4A
This Hall Effect current sensor
is based on open loop principle and can be used for
measurement of DC currents. The output of the transducer
reflects the real wave of the
current carrying conductor.
|

|
|
Product Characteristics |
Applications |
|
|
|
Excellent accuracy |
|
Frequency conversion timing equipments |
|
|
|
Very good linearity |
|
Various power supply |
|
|
|
Small size |
|
Uninterruptible power supplies (UPS) |
|
|
|
Light in weight
Window structure
Less power consumption |
|
Electric welding machines Transformer substation
|
|
|
|
Electrically isolating the output of the transducer from the
current carrying conductor |
|
Electrolyzing and electroplating equipments
Electric powered locomotive
Numerical controlled machine tools |
|
|
|
No insertion loss |
|
Microcomputer monitoring |
|
|
|
Current overload capability |
|
Electric power network monitoring |
|
ELECTRICAL DATA |
|
|
Part number |
Measuring range |
|
Linearity range |
Overload capacity |
|
CYHCT-E4A-10mA-XY
|
10mA |
|
15mA |
200mA |
|
CYHCT-E4A-100mA-XY
|
100mA |
|
150mA |
2A |
|
CYHCT-E4A-200mA-XY
|
200mA |
|
300mA |
4A |
|
CYHCT-E4A-500mA-XY
|
500mA |
|
750mA |
10A |
|
CYHCT-E4A-1A-XY
|
1A |
|
1.5A |
20A |
|
CYHCT-E4A-2A-XY
|
2A |
|
3A |
40A |
|
CYHCT-E4A-5A-XY
|
5A |
|
7.5A |
100A |
|
CYHCT-E4A-10A-XY
|
10A |
|
15A |
200A |
|
Supply voltage Nominal output voltage |
X=1 for ą12Vą5%, X=2 for ą15Vą5% Y=1 for 0-4V, Y=2 for 0-5V
|
V V |
|
Current consumption |
≤25 |
mA |
|
Galvanic isolation |
3KV RMS/50Hz/min |
KV |
|
ACCURACY DYNAMIC PERFORMANCE |
|
Zero offset voltage |
ą20 |
mV |
|
Hysteresis error |
ą10 |
mV |
|
Thermal drift of offset current |
≤250 |
ppm/°C |
|
Response time |
≤10 |
μs |
|
Accuracy |
ą1.0 |
% |
|
Linearity |
≤1.0 |
%FS |
|
GENERAL DATA |
|
Operating temperature |
-10 ~ +80 |
°C |
|
Storage temperature |
-25 ~ +85 |
°C |

CONNECTION
The current carrying cable must pass through the window. The phase
of output is the same that of the current passing the window in the
direction of the arrow indicated on the case.
|
Wiring of Terminals: 1. +15V/+12V Power Supply
|
|
2. -15V/-12V Power Supply |
|
3. +Output |
|
4. Ground |
|
 |
Notes:
1. Connect the terminals of power source, outputs respectively and
correctly, never make wrong connection.
2. Two potentiometers can be adjusted, only if necessary, by turning
slowly to the required accuracy with a small screwdriver.
3. The best accuracy can be achieved when the window is fully filled
with bus-bar (current carrying conductor).
4. The in-phase output can be obtained when the direction of current
of current carrying conductor is the same as the direction of arrow
marked on the transducer case.
Have question?
Please Click Here
for Support
|