Permanent Magnets & Hall Effect Sensors     My Account    |   Track Your Order   |   My Cart    |   F.A.Q.         
    Project Engineering     |     Collaboration Forum     |     Contact Us     |     About Us    |     Site Map       sales@bbautomacao.com


Permanent
Magnets
NdFeb Magnets
Alnico Magnets
SmCo Magnets
H. Ferrite Magnets
Rare Earth Magnets
Bonded NdFeB

Magnet Grades


Project Magnets
Custom Magnets
Industrial Magnets
Motor Magnets
Generator Magnets
Dipole Magnets
Chinese Magnets
Strong Magnets

Neodymium Magnets

Custom Neodymium
Neodymium Rings
Neodymium Bars
Neodymium Blocks
Neodymium Cylinders
Neodymium Discs
Neodymium Spheres
Coated Neodymium

Hall Effect Sensors

Vane Sensors
ICs/Elements
Gear Tooth Sensors
Current Sensors
Voltage Sensors
Analog Sensors
Digital Sensors

Measuring Devices
Gauss/Tesla Meters
Magnetic Fluxmeters
Magnetic Field Viewer


Checkout


Search
Terms & Policies
Magnet manufacturers
Neodymium China

 

 

 
 

Closed Loop Hall Effect Current Sensors/Transducers

Current Sensors with Round Windows

  Principle of Closed Loop Hall Effect Current Sensors
  Price List of Current Sensors with Round Windows

open loop pcb-based | open loop rectangle window | open loop round window
closed loop pcb-based | closed loop rectangle window | closed loop round window

Closed Loop Hall Effect Current Sensor CYHCT-D7-500A-X

This Hall Effect current sensor is based on closed loop compensating principle and can be used for measurement of DC currents. The output of the transducer reflects the real wave of the current carrying conductor.

Electrical Data

 

Part number

CYHCT-D7-500A-X, X=1,2 according to power supply

Measuring range

500

A

Linearity range

750

A

Nominal output current

100±0.5%

mA

Overload capacity

1000

A

Power supply

X=1 for ±12V±5%,

X=2 for ±15V±5%

V

Current consumption

≤25 + output current

mA

Galvanic isolation

3KV RMS/50Hz/min

KV

Accuracy Dynamic Performance

Zero offset current

±0.2

mA

Hysteresis error

±0.2

mA

Thermal drift of offset current

≤200

ppm/°C

Response time

<2

μs

Accuracy

±0.5

%

Linearity

≤0.1

%FS

General Data

Operating temperature

-10 ~ +80

°C

Storage temperature

-25 ~ +85

°C

Connection

The current carrying cable must pass through the window. The phase of output is the same as that of the current passing the window in the direction of the arrow indicated on the case.

Notes:

1. Connect the terminals of power source, outputs respectively and correctly, never make wrong connection.

2. Two potentiometers can be adjusted, only if necessary, by turning slowly to the required accuracy with a small screwdriver.

3. The best accuracy can be achieved when the window is fully filled with bus-bar (current carrying conductor).

4. The in-phase output can be obtained when the direction of current of current carrying conductor is the same as the direction of arrow marked on the transducer case.

Related subjects: electrical current measurement examples, motor current measurement, current measurement for a variable frequency drive, dc/ac UPS inverter


Have  question? Please Click Here for Support

power_transducer_close_loop_threshold
Engineering Forum

 

 

Home | Products | Search | Checkout | About us | Contact us | Site map

© Copyright BB Automacao Inc.

4 Cedar Swamp Rd.
Glen Cove, New York 11
542
nyc@bbautomacao.com
Ph.: 516-277-1278
Fax: 516-776-9353