Permanent Magnets & Hall Effect Sensors     My Account    |   Track Your Order   |   My Cart    |   F.A.Q.         
    Project Engineering     |     Collaboration Forum     |     Contact Us     |     About Us    |     Site Map       sales@bbautomacao.com

Hall Effect Current Sensor/Transducer CY-IZ04-A

Overview of Case Types of Transducer CY-IZ04-A

1. General Specifications
 
Linearity Range 1.5 times of the maximum measuring range Response Time 10µs
Overload Capability 20 times of the maximum measuring range Current Consumption 25mA
Accuracy 1.0% Isolation 3KV RMS/50Hz/min
Offset Voltage 25mV Operating Temperature -10°C ~ +80°C
Hysteresis Error 10mV Storage Temperature -25°C ~ +85°C
Temperature Drift 250ppm/°C Fire Retardancy UL94-V0

2. Input/Output Range and Case Types
 
Part Number Output Range Power Supply Window Dimension (mm) Case Type Measuring Range
CY-IZ04-A

0-4V

0-5V

±12V

±15V

20 ×10 A1 50-600A
Ø23 A2 30-500A
21 × 10 A3 50-600A
0-4V, 0-5V
0-20mA, 4-20mA
33 × 16 A4 100-800A
33 × 11 A5 100-500A
0-4V

0-5V

Ø16 A6 50-400A
Ø20.2 A7 100-500A
Ø20.4 A8 100-400A

3. Product Characteristics

Small size, light in weight, less power consumption, window structure, electrically isolating the output of the transducer from the current carrying conductor, no insertion loss.

4. Applications

These sensors can be used for measuring DC, AC and pulsed currents, for Frequency conversion timing equipment, various power supply, UPS, electric welding machine, transformer substation, numerical control machine tool, electrolyzing equipment, electroplating equipment, electric powered locomotive, microcomputer monitoring, electric power net monitoring.

Overview of Case Types A1-A8 of Transducer CY-IZ04-A


 


North America Office
4101B Broadway #204
L.I.C., New York 11103

nyc@bbautomacao.com
No orders by phone toll-free
Fax: 1-718-841-7216

Central & South Americas
Rua Benjamin Constant, 77 cj 606
Sao Paulo - SP - 01005-000

sp@automacao.com
No orders by phone
Cel.: (11) 3112-1683